Bộ sạc – Tiếng Anh – Update DEC 05
TADA adopts the most classic and mature mixed-mode control full-bridge phase-shifting architecture, which is suitable for low-voltage and high-current power electronic topology. Its reliability and stability are better than LLC modular type. Due to the adoption of mixed mode control and adaptive dead zone control, its module conversion efficiency is basically the same as LLC.
The products adopts the most stable peak current mode control in power electronics and has a wave-by-wave current limiting function. It is the most reliable mode among all control modes in power electronics.
The module comes with a heat dissipation module. The structure of the heat dissipation module at the bottom of the PBB has better shock resistance.
MODEL | TD-450-12 | TD-450-24 | TD-450-48 | TD-450-72 | ||
OUTPUT | BOOST CHARGE VOLTAGE
(Vboost)(default) |
14.4V | 28.8V | 57.6V | 72V | |
FLOAT CHARGE VOLTAGE
(Vfloat)(default) |
13.8V | 27.6V | 55.2V | 69V | ||
CHARGE VOLTAGE RANGE Note.3 | 10.5 ~ 21V | 21 ~ 42V | 42 ~ 80V | 54 ~ 100V | ||
MAX. OUTPUT CURRENT
(CC) Note.4 |
25A | 13.5A | 6.8A | 5.5A | ||
MAX. POWER Note.4 | 420W | 453.6W | 456.96W | 462W | ||
RECOMMENDED BATTERY CAPACITY (AMP HOURS) Note.5 | 90 ~ 300AH | 45 ~ 155AH | 24 ~ 80AH | 19 ~ 64AH | ||
LEAKAGE CURRENT FROM BATTERY (Typ.) | <1mA | |||||
INPUT | VOLTAGE RANGE Note.6 | 90 ~ 264VAC | 127 ~ 370VDC | |||
FREQUENCY RANGE | 47 ~ 63Hz | |||||
POWER FACTOR (Typ.) | PF>0.98/115VAC, PF>0.95/230VAC at full load | |||||
EFFICIENCY (Typ.) Note.7 | 92% | 93% | 93% | 93% | ||
AC CURRENT (Typ.) | 4.5A/115VAC | 2.2A/230VAC | ||||
INRUSH CURRENT (Typ.) | COLD START 50A at 230VAC | |||||
LEAKAGE CURRENT | <0.75mA/240VAC | |||||
PROTECTION | SHORT CIRCUIT Note.8 | Protection type : Constant current limiting, charger will shutdown after 5 sec, re-power on to recover | ||||
OVER VOLTAGE Note.9 | 21.5 ~ 26V | 43 ~ 52V | 82 ~ 100V | 102 ~ 120V | ||
Protection type : Shut down and latch off o/p voltage, re-power on to recover | ||||||
REVERSE POLARITY | Protected internal reverse detection, No damage, re-power on to recover after fault condition is removed | |||||
OVER TEMPERATURE | Shut down O/P voltage, recovers automatically after temperature goes down | |||||
FUNCTION | CHARGING CURVE | 2 or 3 stage selectable through DIP S.W on panel, or SBP-001 with computer | ||||
CHARGING PARAMETERS PROGRAMMABLE | No | |||||
Manual setting: No | ||||||
AUTO RANGING CHARGING CURVE (Typ.) | Please refer to functin manual for more detail (page 8) | |||||
Charging current adjustable 50~100% by via potentiometer on panel (Only for auto ranging mode) | ||||||
RS485 | RS485 communication | |||||
CHARGER OK | The TTL signal out, Charger OK = H(4.5 ~ 5.5V) ;
Charger failure or protection status =L( -0.5 ~ +0.5V) |
|||||
BATTERY FULL SIGNAL | The TTL signal out, Battery full = H(4.5 ~ 5.5V ); Charging = L(-0.5 ~ +0.5V) | |||||
REMOTE CONTROL | Short : Charger normal work Open : Charger stop charging | |||||
TEMPERATURE COMPENSATION | By external NTC | |||||
FAN SPEED CONTROL | Depends on internal temperature | |||||
ENVIRON- MENT | WORK TEMP. | -30 ~ +70℃ (Refer to “Derating Curve”) | ||||
WORKING HUMIDITY | 20 ~ 95% RH non-condensing | |||||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH non-condensing | |||||
TEMP. COEFFICIENT | ±0.05%/℃ (0 ~ 50℃) | |||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes | |||||
OTHER | MTBF | 273.7K hrs min. Telcordia SR-332(Bellcore) ; 83.4K hrs min. MIL-HDBK-217F (25℃) | ||||
DIMENSION | As Design | |||||
PACKING | 1.02Kg; 8pcs/10Kg/1.71CUFT |
MODEL | TD-750-12 | TD-750-24 | TD-750-48 | ||
OUTPUT | BOOST CHARGE VOLTAGE
(Vboost)(default) |
14.4V | 28.8V | 57.6V | |
FLOAT CHARGE VOLTAGE
(Vfloat)(default) |
13.8V | 27.6V | 55.2V | ||
CHARGE VOLTAGE RANGE Note.3 | 10.5 ~ 21V | 21 ~ 42V | 42 ~ 80V | ||
MAX. OUTPUT CURRENT
(CC) Note.4 |
43A | 22.5A | 11.3A | ||
MAX. POWER Note.4 | 722.4W | 756W | 759.36W | ||
RECOMMENDED BATTERY CAPACITY (AMP HOURS) Note.5 | 150 ~ 500AH | 80 ~ 260AH | 40 ~ 130AH | ||
LEAKAGE CURRENT FROM BATTERY (Typ.) | <1mA | ||||
INPUT | VOLTAGE RANGE Note.6 | 90 ~ 264VAC | 127 ~ 370VDC | ||
FREQUENCY RANGE | 47 ~ 63Hz | ||||
POWER FACTOR (Typ.) | PF>0.98/115VAC, PF>0.95/230VAC at full load | ||||
EFFICIENCY (Typ.) Note.7 | 92% | 93% | 93% | ||
AC CURRENT (Typ.) | 8.7A/115VAC | 4A/230VAC | |||
INRUSH CURRENT (Typ.) | COLD START 50A at 230VAC | ||||
LEAKAGE CURRENT | <1mA/240VAC | ||||
PROTECTION | SHORT CIRCUIT Note.8 | Protection type : Constant current limiting, charger will shutdown after 5 sec, re-power on to recover | |||
OVER VOLTAGE Note.9 | 21.5 ~ 26V | 43 ~ 52V | 82 ~ 100V | ||
Protection type : Shut down and latch off o/p voltage, re-power on to recover | |||||
REVERSE POLARITY | Protected internal reverse detection, No damage, re-power on to recover after fault condition is removed | ||||
OVER TEMPERATURE | Shut down O/P voltage, recovers automatically after temperature goes down | ||||
FUNCTION | CHARGING CURVE | 2 or 3 stage selectable through DIP S.W on panel, or SBP-001 with computer | |||
CHARGING PARAMETERS PROGRAMMABLE | No | ||||
Manual setting: No | |||||
AUTO RANGING CHARGING CURVE (Typ.) | Please refer to functin manual for more detail (page 8) | ||||
Charging current adjustable 50~100% by via potentiometer on panel (Only for auto ranging mode) | |||||
CANBUS INTERFACE | CANBus 2.0B, Can control, Setting and monitoring(VO,IO,charging curve, internal temp. and DC output ON/OFF) | ||||
CHARGER OK | The TTL signal out, Charger OK = H(4.5 ~ 5.5V) ;
Charger failure or protection status =L( -0.5 ~ +0.5V) |
||||
BATTERY FULL SIGNAL | The TTL signal out, Battery full = H(4.5 ~ 5.5V ); Charging = L(-0.5 ~ +0.5V) | ||||
REMOTE CONTROL | Short : Charger normal work Open : Charger stop charging | ||||
TEMPERATURE COMPENSATION | By external NTC | ||||
FAN SPEED CONTROL | Depends on internal temperature | ||||
ENVIRON- MENT | WORK TEMP. | -30 ~ +70℃ (Refer to “Derating Curve”) | |||
WORKING HUMIDITY | 20 ~ 95% RH non-condensing | ||||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH non-condensing | ||||
TEMP. COEFFICIENT | ±0.05%/℃ (0 ~ 50℃) | ||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes | ||||
OTHER | MTBF | 227.6K hrs min. | Telcordia SR-332(Bellcore) ; 67.7K hrs min. | MIL-HDBK-217F (25℃) | |
DIMENSION | As Design | ||||
PACKING | 1.84Kg; 4pcs/9Kg/1.63CUFT |
MODEL | TD-750-12-RS485-CHSET | TD-750-24-RS485-CHSET | TD-750-48-RS485-CHSET | ||
OUTPUT | BOOST CHARGE VOLTAGE
(Vboost)(default) |
14.4V | 28.8V | 57.6V | |
FLOAT CHARGE VOLTAGE
(Vfloat)(default) |
13.8V | 27.6V | 55.2V | ||
CHARGE VOLTAGE RANGE Note.3 | 10.5 ~ 21V | 21 ~ 42V | 42 ~ 80V | ||
MAX. OUTPUT CURRENT
(CC) Note.4 |
43A | 22.5A | 11.3A | ||
MAX. POWER Note.4 | 722.4W | 756W | 759.36W | ||
RECOMMENDED BATTERY CAPACITY (AMP HOURS) Note.5 | 150 ~ 500AH | 80 ~ 260AH | 40 ~ 130AH | ||
LEAKAGE CURRENT FROM BATTERY (Typ.) | <1mA | ||||
INPUT | VOLTAGE RANGE Note.6 | 90 ~ 264VAC | 127 ~ 370VDC | ||
FREQUENCY RANGE | 47 ~ 63Hz | ||||
POWER FACTOR (Typ.) | PF>0.98/115VAC, PF>0.95/230VAC at full load | ||||
EFFICIENCY (Typ.) Note.7 | 92% | 93% | 93% | ||
AC CURRENT (Typ.) | 8.7A/115VAC | 4A/230VAC | |||
INRUSH CURRENT (Typ.) | COLD START 50A at 230VAC | ||||
LEAKAGE CURRENT | <1mA/240VAC | ||||
PROTECTION | SHORT CIRCUIT Note.8 | Protection type : Constant current limiting, charger will shutdown after 5 sec, re-power on to recover | |||
OVER VOLTAGE Note.9 | 21.5 ~ 26V | 43 ~ 52V | 82 ~ 100V | ||
Protection type : Shut down and latch off o/p voltage, re-power on to recover | |||||
REVERSE POLARITY | Protected internal reverse detection, No damage, re-power on to recover after fault condition is removed | ||||
OVER TEMPERATURE | Shut down O/P voltage, recovers automatically after temperature goes down | ||||
FUNCTION | CHARGING SET | Set up charging capacity manually | |||
ENVIRON- MENT | WORK TEMP. | -30 ~ +70℃ (Refer to “Derating Curve”) | |||
WORKING HUMIDITY | 20 ~ 95% RH non-condensing | ||||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH non-condensing | ||||
TEMP. COEFFICIENT | ±0.05%/℃ (0 ~ 50℃) | ||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes | ||||
OTHER | MTBF | 227.6K hrs min. | Telcordia SR-332(Bellcore) ; 67.7K hrs min. | MIL-HDBK-217F (25℃) | |
DIMENSION | As Design | ||||
PACKING | 2.5Kg |
MODEL | TD-1200-12 | TD-1200-24 | TD-1200-48 | ||
OUTPUT | BOOST CHARGE VOLTAGE
(Vboost)(default) |
14.4V | 28.8V | 57.6V | |
FLOAT CHARGE VOLTAGE
(Vfloat)(default) |
13.8V | 27.6V | 55.2V | ||
CHARGE VOLTAGE RANGE Note.3 | 10.5 ~ 21V | 21 ~ 42V | 42 ~ 80V | ||
MAX. OUTPUT CURRENT
(CC) Note.4 |
70A | 36A | 18A | ||
MAX. POWER Note.4 | 1176W | 1209.6W | 1209.6W | ||
RECOMMENDED BATTERY CAPACITY (AMP HOURS) Note.5 | 240 ~ 800AH | 120 ~ 420AH | 60 ~ 210AH | ||
LEAKAGE CURRENT FROM BATTERY (Typ.) | <1mA | ||||
INPUT | VOLTAGE RANGE Note.6 | 90 ~ 264VAC | 127 ~ 370VDC | ||
FREQUENCY RANGE | 47 ~ 63Hz | ||||
POWER FACTOR (Typ.) | PF>0.98/115VAC, PF>0.95/230VAC at full load | ||||
EFFICIENCY (Typ.) Note.7 | 92% | 93% | 94% | ||
AC CURRENT (Typ.) | 12A/115VAC | 6.5A/230VAC | |||
INRUSH CURRENT (Typ.) | COLD START 50A at 230VAC | ||||
LEAKAGE CURRENT | <1mA/240VAC | ||||
PROTECTION | SHORT CIRCUIT Note.8 | Protection type : Constant current limiting, charger will shutdown after 5 sec, re-power on to recover | |||
OVER VOLTAGE Note.9 | 21.5 ~ 26V | 43 ~ 52V | 82 ~ 100V | ||
Protection type : Shut down and latch off o/p voltage, re-power on to recover | |||||
REVERSE POLARITY | Protected internal reverse detection, No damage, re-power on to recover after fault condition is removed | ||||
OVER TEMPERATURE | Shut down O/P voltage, recovers automatically after temperature goes down | ||||
FUNCTION | CHARGING CURVE | 2 or 3 stage selectable through DIP S.W on panel, or SBP-001 with computer | |||
CHARGING PARAMETERS PROGRAMMABLE | No | ||||
Manual setting: No | |||||
AUTO RANGING CHARGING CURVE (Typ.) | Please refer to functin manual for more detail (page 8) | ||||
Charging current adjustable 50~100% by via potentiometer on panel (Only for auto ranging mode) | |||||
CANBUS INTERFACE | CANBus 2.0B, Can control, Setting and monitoring(VO,IO,charging curve, internal temp. and DC output ON/OFF) | ||||
CHARGER OK | The TTL signal out, Charger OK = H(4.5 ~ 5.5V) ;
Charger failure or protection status =L( -0.5 ~ +0.5V) |
||||
BATTERY FULL SIGNAL | The TTL signal out, Battery full = H(4.5 ~ 5.5V ); Charging = L(-0.5 ~ +0.5V) | ||||
REMOTE CONTROL | Short : Charger normal work Open : Charger stop charging | ||||
TEMPERATURE COMPENSATION | By external NTC | ||||
FAN SPEED CONTROL | Depends on internal temperature | ||||
ENVIRON- MENT | WORK TEMP. | -30 ~ +70℃ (Refer to “Derating Curve”) | |||
WORKING HUMIDITY | 20 ~ 95% RH non-condensing | ||||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH non-condensing | ||||
TEMP. COEFFICIENT | ±0.05%/℃ (0 ~ 50℃) | ||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes | ||||
OTHER | MTBF | 172.5K hrs min. | Telcordia SR-332(Bellcore) ; 47.5K hrs min. | MIL-HDBK-217F (25℃) | |
DIMENSION | As Design | ||||
PACKING | 1.93Kg; 4pcs/10Kg/1.72CUFT |
MODEL | TD-1700-12 | TD-1700-24 | TD-1700-48 | ||
OUTPUT | BOOST CHARGE VOLTAGE
(Vboost)(default) |
14.4V | 28.8V | 57.6V | |
FLOAT CHARGE VOLTAGE
(Vfloat)(default) |
13.8V | 27.6V | 55.2V | ||
CHARGE VOLTAGE RANGE Note.3 | 10.5 ~ 21V | 21 ~ 42V | 42 ~ 80V | ||
MAX. OUTPUT CURRENT
(CC) Note.4 |
85A | 50A | 25A | ||
MAX. POWER Note.4 | 1428W | 1680W | 1680W | ||
RECOMMENDED BATTERY CAPACITY (AMP HOURS) Note.5 | 300 ~ 1000AH | 200 ~ 640AH | 100 ~ 330AH | ||
LEAKAGE CURRENT FROM BATTERY (Typ.) | <1mA | ||||
INPUT | VOLTAGE RANGE Note.6 | 90 ~ 264VAC | 127 ~ 370VDC | ||
FREQUENCY RANGE | 47 ~ 63Hz | ||||
POWER FACTOR (Typ.) | PF>0.98/115VAC, PF>0.95/230VAC at full load | ||||
EFFICIENCY (Typ.) Note.7 | 92% | 93% | 94% | ||
AC CURRENT (Typ.) | 14.8A/115VAC | 9.3A/230VAC | |||
INRUSH CURRENT (Typ.) | COLD START 50A at 230VAC | ||||
LEAKAGE CURRENT | <0.75mA/240VAC(60335-1/2-29), <1.5mA Peak/240VAC(62368-1) | ||||
PROTECTION | SHORT CIRCUIT Note.8 | Protection type : Constant current limiting, charger will shutdown after 5 sec, re-power on to recover | |||
OVER VOLTAGE Note.9 | 21.5 ~ 26V | 43 ~ 52V | 82 ~ 100V | ||
Protection type : Shut down and latch off o/p voltage, re-power on to recover | |||||
REVERSE POLARITY | Protected internal reverse detection, No damage, re-power on to recover after fault condition is removed | ||||
OVER TEMPERATURE | Shut down O/P voltage, recovers automatically after temperature goes down | ||||
FUNCTION | CHARGING CURVE | 2 or 3 stage selectable through DIP S.W on panel, or SBP-001 with computer | |||
CHARGING PARAMETERS PROGRAMMABLE | No | ||||
Manual setting: No | |||||
AUTO RANGING CHARGING CURVE (Typ.) | Please refer to functin manual for more detail (page 8) | ||||
Charging current adjustable 50~100% by via potentiometer on panel (Only for auto ranging mode) | |||||
CANBUS INTERFACE | CANBus 2.0B, Can control, Setting and monitoring(VO,IO,charging curve, internal temp. and DC output ON/OFF) | ||||
CHARGER OK | The TTL signal out, Charger OK = H(4.5 ~ 5.5V) ;
Charger failure or protection status =L( -0.5 ~ +0.5V) |
||||
BATTERY FULL SIGNAL | The TTL signal out, Battery full = H(4.5 ~ 5.5V ); Charging = L(-0.5 ~ +0.5V) | ||||
REMOTE CONTROL | Short : Charger normal work Open : Charger stop charging | ||||
TEMPERATURE COMPENSATION | By external NTC | ||||
FAN SPEED CONTROL | Depends on internal temperature | ||||
ENVIRON- MENT | WORK TEMP. | -30 ~ +70℃ (Refer to “Derating Curve”) | |||
WORKING HUMIDITY | 20 ~ 95% RH non-condensing | ||||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH non-condensing | ||||
TEMP. COEFFICIENT | ±0.05%/℃ (0 ~ 50℃) | ||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes | ||||
OTHER | MTBF | 190.0K hrs min. | Telcordia SR-332(Bellcore) ; 45.1K hrs min. | MIL-HDBK-217F (25℃) | |
DIMENSION | As Design | ||||
PACKING | 2.93Kg; 4cs/14Kg/2.58CUFT |
Sạc TD-AGV-FC-24-20